AutoDome 800 Series HD PTZ Camera Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 15
Bosch Security Systems, Inc. Installation Manual F.01U.273.797 | 5.0 | 2012.08
2.1.2 Description
This chapter details how to install an AutoDome Pendant Arm to a wall, a corner, or to a mast
(pole). Any variations to the installation procedures are noted.
See Section 3 Installing Roof Parapet and Pipe Mounts, page 33 for a Roof (Parapet) or Pipe
mount installation.
2.1.3 Tools Required
5 mm Allen wrench (supplied)
Small, straight-blade screwdriver - 2.5 mm (0.1 in.)
No. 2 Phillips screwdriver
Socket wrench and 9/16-in. socket
Banding tool (Bosch P/N TC9311PM3T) - if installing a mast (pole) mount
3/4 in. (20-mm) NPS right angle conduit connector - if installing a mast (pole) mount with
a VG4-ARMPLATE
2.2 Pre-installation Checklist
1. Determine the location and distance for the Power Supply Box based on its voltage and
current consumption.
You may choose to route the main power supply through an intermediate power supply
box (VG4-PSU1 or VG4-PSU2) before connecting the power to the pendant arm power
supply box (VG4-PA0). See Section 4 Cable and Wire Standards, page 51, for wiring
information and distances.
2. Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to
ensure that water cannot enter the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
3. Route all rough wiring including: power, Ethernet, alarms I/O, relay I/O, and fiber optic
cabling. See Section 4 Cable and Wire Standards, page 51, for video and control protocol
methods.
4. Choose the appropriate AutoDome model for the environment in which it will be used.
5. Choose the appropriate mounting kit to use, depending on the location of the AutoDome,
either wall mount, corner mount, or mast (pole) mount.
If the kit contains a Power Supply Box, refer to Section 2.3 Mount Power Supply Box,
page 16.
If you are using the Mounting Plate with a 24 V AutoDome, refer to Section 2.8 Installing
the VG4-A-ARMPLATE, page 26.
WARNING!
Power and I/O cabling must be routed separately inside different permanently earthed metal
conduits.
WARNING!
Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.