52 en Cable and Wire StandardsAutoDome 800 Series HD PTZ Camera
Ethernet Media Converter | |
|
|
Fiber Type, SMF | |
| G.652. |
|
|
Maximum Distance | 20 km (12.4 miles) |
|
|
Requirement | Media converter receiver (CNFE2MC/IN) at controller end of |
| system |
|
|
Terminal Connection | Duplex LC or Single SC |
|
|
4.4 | Audio Cables |
| |
|
| The AutoDome 800 Series is capable of receiving line input audio signals and transmitting it | |
|
| over a network. The audio signal is transmitted | |
|
| Audio Line Input Specifications | |
|
|
|
|
|
| Max. Input Voltage | 5.5 Vpp |
|
|
|
|
|
| Impedance | 9K ohm |
|
|
|
|
|
| Sample Rate | 8 K Hz, 16 Bit, mono |
|
|
|
|
|
| Shield | Bare copper braid: 95% coverage |
|
|
|
|
|
| Internal gain level adjustment is available | |
|
|
|
|
|
| Wire Specifications |
|
|
|
|
|
|
| Wire Type | Coax (recommended) |
|
|
|
|
|
| Distance | 10 m (33 ft) |
|
|
|
|
|
| Gage | 22 AWG to connector (P105/P106) |
|
|
|
|
|
| Shield | Bare copper braid: 95% coverage |
|
|
|
|
|
| Center conductor | Stranded bare copper |
|
|
|
|
NOTICE! Separate the audio cables from the AC power lines to avoid noise.
Audio Connections
1.Remove the 100 Ohm termination resistor from the terminals.
2.Connect the audio line level source to the Audio+ (C+) input terminal.
3.Connect the audio signal ground to the Audio-
The following figure illustrates the connections for audio over an IP network.
Figure 4.1 Connections for audio over an Ethernet network
F.01U.273.797 5.0 2012.08 | Installation Manual | Bosch Security Systems, Inc. |