AutoDome 800 Series HD PTZ CameraInstalling Roof Parapet and Pipe Mounts en 37

3.4Route Wires and Attach Connectors

Power wires must be routed to the left (front) side of the Power Supply Box through a separate conduit. All video, control, and alarm wires must be routed through a second conduit to the right side of the box. See Section 4 Cable and Wire Standards, page 51 for methods of transmitting video and data, and for wire specifications.

WARNING!

External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in accordance to local country codes for all other countries.

Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation. A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm must be incorporated.

There are two possible methods to route the video, control, and alarm wires:

One is to route the power, ethernet, and alarm wires through the conduit fitting on the right (front) side of the Power Supply Box and out to the AutoDome Interface Board.

J101

(FUSE)

XF101

P101

24V NC 24V

P106

J102

P107

P105

 

 

XF103

)

DOME

2 1

(FUSE

HTR

5 4 3

(FUSE)

J103

 

XF102

(LED)

 

 

GND TXD RXD  C+ C- GND TXD RXD  C+ C-

Figure 3.3 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box

1

120 VAC/230 VAC Power In

5

Ethernet Video and Control Wire

2

P101 Connector

6

24 VAC Power Out

3

Ground Connection

7

P107 Connector

4

Transformer

 

 

The second method is to bypass the Power Supply Box and route the ethernet and alarm wires directly to the Interface Board. You connect only the power wires inside the Power Supply Box.

Bosch Security Systems, Inc.

Installation Manual

F.01U.273.797 5.0 2012.08

Page 37
Image 37
Bosch Appliances VG5 800 SERIES 4Route Wires and Attach Connectors, VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box