AutoDome 800 Series HD PTZ CameraInstalling Roof Parapet and Pipe Mounts en 39
3.4.1Wiring the Power Supply Box
1. Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of the box.
NOTICE! The Power Supply Box with transformer comes with a barrier that separates the high voltage side on the left from the low voltage 24 VAC side on the right.
2.Cut and trim the high voltage 115/230 VAC power and ground wires with sufficient slack to reach their connector terminal in the box, but not so long as to be pinched by or to obstruct closing the Cover Door. See Section 3.1.1 Parts List, page 33, for connector location.
3.Attach the supplied
4.Route the low power 24 VAC wires from the right side of the Power Supply Box out to where the AutoDome will be mounted. Attach the supplied
5.Route the Ethernet cable out to where the AutoDome will be mounted. See Section 4 Cable and Wire Standards, page 51 for fiber optic specifications.
NOTICE! All ethernet and alarm wires either pass through the Power Supply Box or
3.4.2Wiring the Fiber Optic Model
If installing a Fiber Optic model, bring the fiber optic cable into the right side of the power supply box.