Bosch Appliances VG5 800 SERIES Advanced Mode Interfaces Alarm Inputs, Relay, Idle State

Models: VG5 800 SERIES

1 123
Download 123 pages 19.26 Kb
Page 104
Image 104

104 en Configuring the AutoDome 800 Series

AutoDome 800 Series HD PTZ Camera

 

 

3.Choose one of the following output commands for both Output 1 and Output 2 settings:

None: no defined command.

Alarm Relay: defines a physical connection from the open collector alarm output.

Aux On: defines a standard or custom keyboard ON command.

Refer to Section A Keyboard Commands by Number, page 116, for a list of valid com- mands.

Note: Only commands 1, 2, 8, 18, 20, 43, 60, 78, 80, 86 are supported. Support for the remaining commands is scheduled for a future release.

Aux Off: defines a standard or custom keyboard OFF command.

Refer to Section A Keyboard Commands by Number, page 116, for a list of valid com- mands.

Note: Only commands 1, 2, 8, 18, 20, 43, 60, 78, 80, 86 are supported. Support for the remaining commands is scheduled for a future release.

Shot: defines a preset scene from shot 1-99.

4.Click Set to save and to activate the alarm rules.

7.45Advanced Mode: Interfaces

7.46Alarm Inputs

Select the type of input for each physical alarm. Select from either N.O. (Normally Open) or N.C. (Normally Closed) and provide an optional name for each input.

7.47Relay

You can configure the switching behavior of the relay outputs. For each relay, you can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).

You can also specify whether an output should operate as a bistable or monostable relay. In bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set the time after which the relay will return to the idle state.

You can select different events that automatically activate an output. It is possible, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped.

Idle State

Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.

Operating Mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Relay Follows

Select one of the following actions that the AutoDome performs after the relay is triggered:

Off

Connection

Video Alarm 1

Motion Alarm 1

Local Input 1

F.01U.273.797 5.0 2012.08

Installation Manual

Bosch Security Systems, Inc.

Page 104
Image 104
Bosch Appliances VG5 800 SERIES Advanced Mode Interfaces Alarm Inputs, Idle State, Operating Mode, s Relay Follows