Alarms and Relay Connections en 55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.2 N.C. Normally Closed Non-supervised Connections

1

Dry Contact

3

Dome Connector

2

Alarm Inputs 1 to 2

4

Ground

2.From the Alarm Connections page on the Settings Page (Section 7.39 Alarm Connections, page 95) the Alarm Input # to N.C. See the table below for contact and condition details.

 

 

AutoDome Programmed N.C.

 

 

 

 

 

 

 

 

Circuit

Alarm Indication

 

 

 

 

 

 

 

 

Open

Alarm

 

 

 

 

 

 

 

 

Closed

Normal

 

 

 

 

 

 

5.3

Configuring an Open Collector Output

The AutoDome incorporates one (1) open collector output.

This output must be connected to a positive voltage between 5 and 32 V to complete the circuit, with a maximum voltage rating of 32 VDC @ 150 ma.

1.Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the transistor.

2.Connect the appropriate stripped wire to the ground (GND) connector.

Bosch Security Systems, Inc.

Installation Manual

F.01U.273.797 5.0 2012.08