AutoDome 800 Series HD PTZ CameraUsing the AutoDome 800 Series en 61
6.5.2 | Guidelines for Implementing Intelligent Tracking | |
| Factors such as the viewing angle and unwanted motion (from trees, for example) may | |
| interfere with Intelligent Tracking operation. Use the following recommendations to ensure | |
| smooth Intelligent Tracking operation: | |
| – | Mount/Mounting Surface Stability |
|
| – Mount the camera in the most stable position. Avoid locations affected by vibrations, |
|
| such as those caused by a |
|
| complications when the camera |
|
| – Use the pendant arm mount, if possible. This mount option provides the most |
|
| stability for the camera. |
|
| – Use guy wires to protect against strong winds if using the parapet mount. |
| – | Field of View |
|
| – Select a location and viewing angle that allows the flow of people to move across |
|
| the camera’s field of view. |
|
| – Avoid motion that moves directly towards the camera. |
|
| – Avoid locations that attract large numbers of people, such as retail stores or |
|
| intersections. Intelligent Tracking is optimized for scenes with very few moving |
|
| objects. |
| – | Unwanted Motion |
|
| – Avoid neon lights, flashing lights, night time lights, and reflected light (from a |
|
| window or mirror, for example). The flickering of these lights can affect the |
|
| Intelligent Tracking operation. |
6.6The Livepage
Once the connection is established, the Web browser displays the Livepage. It shows the live video image on the right of the browser window. Depending on the configuration, various text overlays may be visible on the live video image.
Other information may be shown next to live video image on the Livepage. The display depends on the settings on the Livepage Configuration page (see the AutoDome 800 Series online help).
Display Stamping
Various overlays or “stamps” in the video image provide important status information. The overlays provide the following information:
Decoding error. The frame might show artefacts due to decoding errors. If subsequent frames reference this corrupted frame, they might also show decoding errors as well but won’t be marked with the “decoding error” icon.
Alarm flag set on media item
Communication error. Any kind of communication error is visualized by this icon. Cause can be a connection failure to the storage medium, a protocol violation with a sub component or simply a timeout. An automatic reconnection procedure is started in the background in order to recover from this error.
Gap; no video recorded
Watermarking not valid
Watermarking flag set on media item
Bosch Security Systems, Inc. | Installation Manual | F.01U.273.797 5.0 2012.08 |