Bosch Appliances VG5 800 SERIES Pin Alarm Output Flying Lead Pin Alarm Input Flying Lead

Models: VG5 800 SERIES

1 123
Download 123 pages 19.26 Kb
Page 18
Image 18

18 en Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts

AutoDome 800 Series HD PTZ Camera

 

 

4.Attach the supplied 3-pin Power Plug to the incoming power wires. See connector P101 in Table 2.1, Page 20, for wire connections.

5.Attach an RJ45 plug to the incoming Ethernet cable. If installing a Fiber Optic model, attach an ST fiber plug to the optic fiber cable. See Section 4 Cable and Wire Standards, page 51, for the different methods of transmitting video and control protocols, and wire specifications.

6.If you are connecting alarm inputs and relay outputs, attach the supplied 4-wire Alarm Output and the 6-wire Alarm Input flying leads to the appropriate relay and alarm wires.

WIRE

1WHITE

2BROWN

3ORANGE

4GREEN

WIRE

1WHITE

2BROWN

3ORANGE

4GREEN

5YELLOW

6BLUE

Figure 2.3 Alarm and relay connectors

1

4-pin Alarm Output Flying Lead

2

6-pin Alarm Input Flying Lead

Wire

Color

Description

Wire

Color

Description

1

White

Not used

1

White

Alarm Input 1 (A3)

2

Brown

Not used

2

Brown

Alarm Input 2 (A4)

3

Orange

Relay Out 1

3

Orange

Not used

4

Green

Relay Ground

4

Green

Not used

 

 

 

5

Yellow

Not used

 

 

 

6

Blue

Alarm Ground (AGND)

 

 

 

 

 

 

F.01U.273.797 5.0 2012.08

Installation Manual

Bosch Security Systems, Inc.

Page 18
Image 18
Bosch Appliances VG5 800 SERIES Pin Alarm Output Flying Lead Pin Alarm Input Flying Lead, Alarm and relay connectors