AutoDome 800 Series HD PTZ CameraInstalling Roof Parapet and Pipe Mounts en 47

 

 

Ref.

Description

Connector

Wire Gauge

Pin

Description

 

 

3

6-pin Alarm Input Flying Lead

P103

 

1

Alarm In 1

 

 

 

Alarms In (1-2)

 

 

2

Alarm In 2

 

 

 

 

 

 

3

Not used

 

 

 

 

 

 

4

Not used

 

 

 

 

 

 

5

Not used

 

 

 

 

 

 

6

Alarm Ground

 

 

4

4-pin Alarm Outputs Flying Lead

P102

 

1

Not used

 

 

 

Relay Out (1)

 

 

2

Not used

 

 

 

 

 

 

3

Relay Out 1

 

 

 

 

 

 

4

Relay Ground

 

 

5

100 Ω Resistor

P105

 

 

 

 

 

6

Audio

P105

 

1

Audio- (C-)

 

 

 

 

 

 

2

Audio+ (C+)

 

 

 

 

 

 

3

NC

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

5

NC

 

 

 

 

 

 

 

NC

 

 

7

Not Used

P104

 

 

 

 

 

8

Not Used

P104

 

 

 

 

 

9

Dome Power

P101

AWG 18-14

3

Dome 24 VAC

 

 

 

 

 

 

2

Earth Ground

 

 

 

 

 

 

1

Dome 24 VAC

 

 

10

Heater Power

P107

AWG 18-14

2

Heater 24 VAC

 

 

 

 

 

 

1

Heater 24 VAC

 

 

11

RJ45 Ethernet Video and Control

J101

 

 

 

 

 

12

To AutoDome

 

 

 

 

3.7.1

Connecting Wires to the Pipe Interface Board

 

 

The Pipe Interface Board contains all of the connectors for control, data, image, and power wires. Follow the procedures below to make the proper connections.

WARNING!

Use a 24 VAC Class 2 power supply only.

1.Attach an RJ45 connector plug to the Ethernet cable and connect the plug to its mating connector J101 on the Pipe Interface Board.

2.Attach the control data in/out wires to their respective terminals on the P105 connector on the Pipe Interface Board. See Figure 3.10, Page 46, for an illustration of these connections.

3.Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board. If this model has a heater, connect the 24 VAC heater power wires to connector P107.

CAUTION!

To protect the AutoDome from damage due to cold temperatures, ensure that you connect the 24 VAC heater power wires to the P101 connector.

4.To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin Alarms Out connector plugs with flying leads to the appropriate alarm wires. Then connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board.

Bosch Security Systems, Inc.

Installation Manual

F.01U.273.797 5.0 2012.08

Page 47
Image 47
Bosch Appliances VG5 800 SERIES Connecting Wires to the Pipe Interface Board, Description Connector Wire Gauge Pin