AutoDome 800 Series HD PTZ Camera

Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts en 17

 

 

 

6. Attach 3/4-inch (20-mm) NPS watertight pipe fittings (not supplied) to the bottom or

 

back holes of the Power Supply Box through which you will run the power, video, and

 

control data wires.

2.4

Route Wires and Attach Connectors

 

Power wires must be routed to the left (front) side of the power supply box through a

separate conduit. All video, control, and alarm wires must be routed through a second conduit to the right side of the box.

If you plan to route the power through an intermediate power supply box, refer to Section 2.5 Route Power through Intermediate Power Supply Box, page 20.

WARNING!

External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in accordance to local country codes for all other countries.

Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation. A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm must be incorporated.

J101

XF101

P101

24V NC 24V

P106

 

 

 

 

 

 

 

GND TXD RXD

C+ C-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J102

 

XF103

24 VAC

P107

HTRDOME 3452 1

 

J103

 

XF102

 

(LED)

 

P105

GND TXD RXD  C+ C-

Figure 2.2 Pendant Arm Power Supply Box

1.Route all network, control, and alarm wires through the conduit fitting on the right side of the power box. See Section 4 Cable and Wire Standards, page 51, for fiber optic specifications and distances.

2.Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of the box. The Power Supply Box with a transformer comes with a barrier that separates the high voltage side on the left, from the low voltage 24 VAC side on the right.

3.Cut and trim all wires with sufficient slack to reach their connector terminals in the box, but not so long as to be pinched by or to obstruct closing the Pendant Arm. See Figure 2.2, Page 17, above, for the connector locations.

Bosch Security Systems, Inc.

Installation Manual

F.01U.273.797 5.0 2012.08

Page 17
Image 17
Bosch Appliances VG5 800 SERIES installation manual Route Wires and Attach Connectors, Pendant Arm Power Supply Box