34 en Installing Roof Parapet and Pipe MountsAutoDome 800 Series HD PTZ Camera

3.2

Pre-installation Check List

 

1.

Determine the location and distance for the power supply box based on its voltage and

 

 

current consumption. See Section 4 Cable and Wire Standards, page 51 for wiring

 

 

information and distances.

 

2.

Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to

 

 

ensure that water cannot enter the box. You must use water tight conduits and fittings to

 

 

meet NEMA 4 standards.

NOTICE! Power and I/O cabling must be routed separately inside different permanently earthed metal conduits.

3.Install all rough wiring including: power, Ethernet, alarms I/O, relay I/O, and fiber optic cabling. See Section 4 Cable and Wire Standards, page 51 for video and control protocol methods.

WARNING!

External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in accordance to local country codes for all other countries.

Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation. A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm must be incorporated.

4.Choose the appropriate AutoDome model for the environment in which it will be used.

5.Choose the appropriate mounting kit to use depending on the location of the AutoDome: Parapet (Roof) mount or the Pipe mount.

CAUTION!

Select a rigid mounting location to prevent excessive vibration to the AutoDome camera.

3.3Mount Power Supply Box

Before mounting the Power Supply Box decide if you will be wiring the box through the holes in the bottom or back of the box. If wiring the box through the back, move the two (2) seal plugs to the bottom holes before mounting.

NOTICE! Use 3/4-inch NPS (20-mm) fittings for the holes on the bottom and back of the box. Use 1/2-inch NPS (15-mm) fittings for the side holes. See Section 3.1.1 Parts List, page 33, for an illustration.

F.01U.273.797 5.0 2012.08

Installation Manual

Bosch Security Systems, Inc.

Page 34
Image 34
Bosch Appliances VG5 800 SERIES installation manual Pre-installation Check List, 3Mount Power Supply Box