AutoDome 800 Series HD PTZ CameraInstalling the Pendant Arm Wall, Corner, and Mast (Pole) Mounts en 21
1 | 120/230 VAC Power In | 5 | Transformer |
2 | Ground Wire | 6 | In/Out Conduit (1/2 in. [15 mm] NPS Fitting |
3 | P101 Connector | 7 | 24 VAC Power Out to |
4 | P107 Connector |
|
|
To properly wire the incoming high voltage and the outgoing low voltage lines, refer to this table:
No. | Connector | Pin 1 | Pin 2 | Pin 3 | Pin 4 | Pin 5 | Pin 6 |
|
|
|
|
|
|
|
|
| Ground | Grounding Screw |
|
|
|
| |
|
|
|
|
|
|
|
|
P101 | 115/230 VAC Power In | Line | NC | Neutral |
|
|
|
|
|
|
|
|
|
|
|
P107 | 24 VAC Power Out |
|
| Earth | Heater | Heater |
|
|
|
|
| Ground | (24 VAC) | (24 VAC) |
|
|
|
|
|
|
|
|
|
Table 2.2
1.Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of the box. The Power Supply Box with a transformer comes with a barrier that separates the high voltage side on the left, from the low voltage 24 VAC side on the right.
2.Cut and trim the high voltage 115/230 VAC power and ground wires with sufficient slack to reach their connector terminal in the box, but not so long as to be pinched by or to obstruct closing the cover door.
3.Attach the supplied
P101 |
24V NC 24V |
1 2 3 |
Figure 2.6 Incoming 115/230 VAC power supply
4.Attach the ground wire to the grounding screw.
5.Connect three wires to the P107 Power Out connector to route the 24 VAC power supply to the
a.Connect the first wire to pin 5 (HN: Heater Neutral) connector.
b.Connect the second wire to pin 4 (HL: Heater Line) connector.
c.Connect the third wire to pin 3 (Earth Ground) connector.
Refer to connector P107 in Table 2.2 and to the image below for an illustration of these connections:
P107
DOME | 2 1 |
HTR | 5 4 3 |
Figure 2.7 Outgoing 24 VAC power supply
Bosch Security Systems, Inc. | Installation Manual | F.01U.273.797 5.0 2012.08 |