Standard recording

Here you can select the mode for standard recordings.

If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Pre- alarm option, recording will only take place in the pre-alarm time, during the alarm and during the set post-alarm time.

If you select Off, no automatic recording takes place.

CAUTION!

You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time (see Section 7.35 Retention Time, page 94).

Standard profile

From this field, you can select the encoder profile to be used for recording (see

Section 7.19 Encoder Profile, page 80).

NOTICE!

The recording profile can deviate from the standard setting Active profile and is only used during an active recording.

Pre-alarm Time

You can select the required pre-alarm time from the list field.

Post-alarm Time

You can select the required post-alarm time from the list field.

Post-alarm profile

You can select the encoder profile to be used for recording during the post-alarm time (see Section 7.19 Encoder Profile, page 80).

The Standard profile option adopts the selection at the top of the page.

Alarm input / Motion alarm / Video loss alarm

Here you can select the alarm sensor that is to trigger a recording.

Virtual alarm

Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.

NOTICE!

For more information, please see the Alarm Task Script Language document and the RCP+ documentation. These documents can be found on the product CD supplied.

Recording includes

You can specify whether, in addition to video data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.

CAUTION!

Without metadata, it is not possible to include video content analysis in recordings.

Bosch Security Systems, Inc.