AutoDome 800 Series HD PTZ Camera

Configuring the AutoDome 800 Series en 95

 

 

Time periods

You can change the names of the recording profiles.

1.Click a profile and then the Rename button.

2.Enter your chosen name and then click the Rename button again.

Activating the Recording

After completing configuration you must activate the recording scheduler and start the recording. Once recording is underway, the Recording Profiles and Recording Scheduler pages are deactivated and the configuration cannot be modified.

You can stop the recording activity at any time and modify the settings.

1.Click the Start button to activate the recording scheduler.

2.Click the Stop button to deactivate the recording scheduler. Running recordings are interrupted and the configuration can be changed.

Recording status

The graphic indicates the recording activity of the AutoDome 800 Series. You will see an animated graphic while recording is taking place.

7.37Recording Status

Certain details on the recording status are displayed here for information purposes. You cannot change any of these settings.

7.38Advanced Mode: Alarm

7.39Alarm Connections

You can select how the AutoDome 800 Series responds to an alarm. In the event of an alarm, the unit can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the AutoDome 800 Series will connect in sequence in the event of an alarm, until a connection is made.

Connect on alarm

Select On so that the AutoDome 800 Series automatically connects to a predefined IP address in the event of an alarm.

By setting Follows input 1 the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.

NOTICE!

In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind when assigning the profile (see Section 7.19 Encoder Profile, page 80).

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.

Destination IP address

For each number, enter the corresponding IP address for the desired remote station.

Destination password

If the remote station is password protected, enter the password here.

In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations

Bosch Security Systems, Inc.

Installation Manual

F.01U.273.797 5.0 2012.08

Page 95
Image 95
Bosch Appliances VG5 800 SERIES installation manual Recording Status, Advanced Mode Alarm Alarm Connections