90 en Configuring the AutoDome 800 Series

AutoDome 800 Series HD PTZ Camera

 

 

To define a title for sectors:

1.Place the cursor in the input box to the right of the sector number.

2.Type a title for the sector, up to 20 characters long.

3.To blank the sector, click the check box to the right of the sector title.

7.28Miscellaneous

Address

Allows the appropriate dome to be operated via the numerical address in the control system. Type a number between 0000 and 9999, inclusive, to identify the camera.

7.29Logs

To save the log file information:

1.Click Download to obtain the log information.

2.Click Save.

3.Navigate to the directory in which you want to store the log information.

4.Type a name for the log file and click Save.

7.30Audio

You can set the gain of the audio signals to suit your specific requirements. The current video image is shown in the small window next to the slide controls to help you check the audio source and improve assignments. Your changes are effective immediately.

If you connect via Web browser, you must activate the audio transmission on the Livepage Functions page (see Section 6.6 The Livepage, page 61). For other connections, the transmission depends on the audio settings of the respective system.

Audio

The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps for each connection. If you do not want any audio data to be transmitted, select Off.

Line In

You can set the line input gain. Make sure that the display does not go beyond the green zone during modulation.

Record Format

Select a format for audio recording. The default value is G.711. Select L16 or AAC (Advanced Audio Coding) if you want better audio quality with higher sampling rates. The L16 standard requires approx. eight times the G.711 bandwidth.

7.31Pixel Counter

Counts the number of pixels in a defined image area. The pixel counter allows the installer to easily verify that the camera installation fulfills any regulatory or specific customer requirements, for example, calculating the pixel resolution of the face of a person passing a doorway monitored by the camera.