Thermal Management

This chapter describes the 21264/EV67 thermal management and thermal design considerations, and is organized as follows:

Operating temperature

Heat sink specifications

Thermal design considerations

10.1Operating Temperature

The 21264/EV67 is specified to operate when the temperature at the center of the heat sink (Tc) is as shown in Table 10–1.Temperature T c should be measured at the center of the heat sink, between the two package studs. The GRAFOIL pad is the interface mate- rial between the package and the heat sink.

Table 10–1 Operating Temperature at Heat Sink Center (Tc)

Tc

Frequency

80.2° C

600 MHz

78.1° C

667 MHz

76.9° C

700 MHz

76.0° C

733 MHz

75.4° C

750 MHz

72.7° C

833 MHz

 

 

Note:

Compaq recommends using the heat sink because it greatly improves the

 

ambient temperature requirement.

Alpha 21264/EV67 Hardware Reference Manual