Fostex VR800 owner manual 111, Data Type

Models: VR800

1 122
Download 122 pages 2.66 Kb
Page 111
Image 111

 

 

VR800 Owner’s Manual (MIDI Implementation Chart/MMC List)

Data Type

 

 

 

 

 

 

 

 

 

 

<loop op . mode>

12=stop

 

 

Indicates the next operating mode following locating to the start point (GP3) upon arriving

 

 

at the end point (GP6) by the play mode. In VR800, 12=stop only is effective.

 

<post locate mode>

12=stop

 

 

 

15=play

 

 

Specifies operating mode in which VR800 should enter upon completing the locate

 

 

operation. Corresponds to the setting of AUTO PLAY ON ("15")/OFF ("12") on the main

 

 

unit.

 

<count>

01 ~ 7F

 

 

 

Specifies succeeding data byte numbers.

 

<mmc track>

Complies to the MMC (MIDI Machine Control) standard track bit map.

 

 

 

In VR800, you always need to specify two byte combinations of "r0" and "r1."

 

<edit message>

00 = no message

 

 

 

01

= completed (completion flag)

 

 

02

= active (execution flag)

 

 

02<mmc time> = Indicates unprocessed time by active (execution flag) and <mmc time>.

 

 

02<count><mmc track> = Indicates source track by active (execution flag) and <mmc

 

 

track>. Used for clipboard play.

 

 

03

= cancel (execution stop)

 

 

05

= Indicates rehearsal (rehearsal mode of auto rec). Possible of undo.

 

 

06

= Indicates take (take mode of auto rec). Possible of undo.

 

 

10

= over value error

 

 

10

<mmc time> = Capacity shortage time is indicated by over value error (error by

 

 

capacity shortage) and <mmc time>. In copy paste, it indicates capacity shortage time

 

 

required for a minimum one time paste.

 

 

11

= Indicates in point error (incorrect in point).

 

 

12

= Indicates out point error (incorrect out point).

 

 

14

= Indicates void data (data necessary for paste does not exist).

 

 

18

= Indicates track select error (track necessary to execute copy/move or erase/cut is not

 

 

correctly setup).

 

 

19<repeat count> = Indicates repeat number error and repeat numbers executable by

 

 

<repeat count>.

 

 

1A = Indicates disable rec (record disable mode).

 

 

25

= Indicates can't undo rehearsal (rehearsal mode of auto rec). Impossible to undo.

 

 

26

= Indicates can't undo take (take mode of auto rec). Impossible toundo.

 

 

71

= Indicates on.

 

 

72

= Indicates off.

 

<mmc time>

hr mn sc fr {ff/st} complies to the MMC standard time code.

 

<on/off>

70 = default

 

 

 

71

= on

 

 

72

= off

 

<repeat count>

01 ~ 7F

 

 

Especially when executing commands such as paste, the number of pasting times to be

 

 

continuously repeated following the auto punch in point is specified.

 

<channel>

00 ~ 08, 7F

 

 

 

Select recorder tracks 1~8. "00" in particular, is not specified (default setting). "7F"

 

 

indicates input/output of Adat optical. For details, refer to explanation on setting the

 

 

Command/Mode.

 

<lock enable>

00 = lock disable, chase disable

 

 

 

01

= lock enable, chase enable

 

 

Corresponds to SLAVE ON ("01")/OFF ("00") in the main unit.

 

<lock status>

00 = lock disable, chase disable

 

 

 

01

= lock enable (unlocked), chase enable (unlocked)

 

 

11

= lock enable (locked), chase enable (locked)

 

<program>

01 ~ 7F

 

 

Indicates program numbers (P1 ~ P99) on the main unit. However, VR800 can specify

 

 

only 01 (corresponds to P01) ~ 63H (corresponds to P99).

 

<lock mode>

40 = Free

 

 

 

42

= Vari

 

 

Indicates the slave mode when this equipment is set to slave ON.

 

 

 

 

 

 

 

111

Page 111
Image 111
Fostex VR800 owner manual 111, Data Type