3–62

“H” Group: Motor Constants Functions

“H” Group: Motor Constants Functions

Introduction

The “H” Group parameters configure the

 

inverter for the motor characteristics. You

 

must manually set H003 and H004 values

 

to match the motor. Most of the remaining

 

parameters are related to vector control, and

 

are in use only when function A044 is set

 

for one of the vector control modes as

 

shown in the diagram. The procedure in

 

“Auto-tuning of Motor Constants” on

 

page 4–67 automatically sets all the param-

 

eters related to vector control. If you

 

configure the inverter to use vector control,

 

we highly recommend letting the auto-

 

tuning procedure derive the values for you.

 

If you want to reset the parameters to the

 

factory default settings, use the procedure

 

in “Restoring Factory Default Settings” on

 

page 6–9.

Inverter Torque Control Algorithms

V/f control,

00

 

 

 

 

A044

 

 

 

 

 

 

 

 

 

constant torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V/f control,

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

variable torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V/f control, free-

02

 

 

 

 

 

 

 

 

setting curve

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensorless vector

03

 

 

 

 

 

 

 

 

(SLV) control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensorless vector,

04

 

 

 

 

 

 

 

 

0Hz domain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vector control with 05 sensor

NOTE: The auto-tuning procedure and related warning messages are in “Auto-tuning of Motor

Constants” on page 4–67. Please read these before trying to auto-tune the motor parameters.

 

 

“H” Function

Run

 

Defaults

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

Units

SRW Display

 

 

 

 

 

 

 

 

 

 

 

 

Func.

 

 

 

Edit

–FE

–FU

 

–FR

 

 

Name

 

Description

 

 

 

 

 

 

Code

 

Lo Hi

(EU)

(US)

 

(JP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H001

Auto-tuning Setting

Three states for auto-tuning

✘ ✘

00

00

 

00

>H001 AUX

 

 

 

 

function, option codes:

 

 

 

 

 

 

AUTO

NOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

Auto-tuning OFF

 

 

 

 

 

 

 

 

 

 

 

 

01

Auto-tune (measure

 

 

 

 

 

 

 

 

 

 

 

 

 

motor resistance and

 

 

 

 

 

 

 

 

 

 

 

 

 

inductance, without

 

 

 

 

 

 

 

 

 

 

 

 

 

rotating)

 

 

 

 

 

 

 

 

 

 

 

 

02

Auto-tune (rotate motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H002

Motor data selection,

Select one of three motor

✘ ✘

00

00

 

00

>H002 AUX

 

 

 

1st motor

parameter sets, 3 options:

 

 

 

 

 

 

DATA

NOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

Standard motor data

 

 

 

 

 

 

 

 

 

 

 

 

01

Auto-tuning data

 

 

 

 

 

 

 

 

 

 

 

 

02

Adaptive tuning data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H202

Motor data selection,

Select one of three motor

✘ ✘

00

00

 

00

>H202 2AUX

 

 

 

2nd motor

parameter sets, 3 options:

 

 

 

 

 

 

DATA

NOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

Standard motor data

 

 

 

 

 

 

 

 

 

 

 

 

01

Auto-tuning data

 

 

 

 

 

 

 

 

 

 

 

 

02

Adaptive tuning data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H003

Motor capacity, 1st

Select 0.2 to 75.0kW for

✘ ✘

Factory set

kW

>H003 AUX

 

 

 

motor

models up to –550xxx,

 

 

 

 

 

 

K

003.70kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2 to 160.0kW for models

 

 

 

 

 

 

 

 

 

 

 

 

–750xxx to –1500xxx