SJ300 Inverter
The data in the receive frame contains
No. | Monitor Item | Units | Multiplier |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | Output frequency | Hz | 100 |
|
|
|
|
|
|
|
|
2 | Output current | A | 10 |
|
|
|
|
|
|
|
|
3 | Direction of rotation | — | — |
|
|
|
|
|
|
|
|
4 | PID feedback monitor | % | 100 |
|
|
| |||||
|
|
|
|
|
|
5 | Intelligent input monitor | — | — |
| BAppendix |
|
|
|
|
| |
6 | Intelligent output monitor | — | — |
| |
|
| ||||
|
|
|
|
|
|
7 | Frequency converting monitor | — | 100 |
|
|
|
|
|
|
|
|
8 | Output torque monitor | % | 1 |
|
|
|
|
|
|
|
|
9 | Output voltage monitor | V | 10 |
|
|
|
|
|
|
|
|
10 | Electric power monitor | kW | 10 |
|
|
|
|
|
|
|
|
11 | Reserved | — | — |
|
|
|
|
|
|
|
|
12 | Run Mode time monitor | hours | 1 |
|
|
|
|
|
|
|
|
13 | Power ON time monitor | hours | 1 |
|
|
|
|
|
|
|
|
The eight bytes for intelligent input or intelligent output data have a bit set in the data field for each I/O point that is ON, according to the following table:
Terminal | Monitor Item | Data |
|
|
|
|
|
|
[FW] | Forward input | 00000001 |
|
|
|
[1] | Input 1 | 00000002 |
|
|
|
[2] | Input 2 | 00000004 |
|
|
|
[3] | Input 3 | 00000008 |
|
|
|
[4] | Input 4 | 00000010 |
|
|
|
[5] | Input 5 | 00000020 |
|
|
|
[6] | Input 6 | 00000040 |
|
|
|
[7] | Input 7 | 00000080 |
|
|
|
[8] | Input 8 | 00000100 |
|
|
|
[AL] | Alarm relay | 00000001 |
|
|
|
[11] | Output 1 | 00000002 |
|
|
|
[12] | Output 2 | 00000004 |
|
|
|
[13] | Output 3 | 00000008 |
|
|
|
[14] | Output 4 | 00000010 |
|
|
|
[15] | Output 5 | 00000020 |
|
|
|