SJ300 Inverter

 

C–9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“B” Group Parameters

 

Default Setting

 

User

 

 

 

 

 

 

 

 

 

 

 

 

 

Func.

 

 

 

 

 

 

 

 

Name

-FE (Europe)

-FU (U.S.)

-FR (Japan)

Setting

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B084

Initialization mode (parameters or

00

00

00

 

 

 

 

 

 

 

trip history)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B085

Country code for initialization

01

02

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B086

Frequency scaling conversion factor

1.0

1.0

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B087

STOP key enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B088

Restart mode after FRS

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B090

Dynamic braking usage ratio

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B091

Stop mode selection

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B092

Cooling fan control

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B095

Dynamic braking control

00

00

00

 

 

 

 

Appendix

 

 

 

 

 

 

 

 

 

 

 

B096

Dynamic braking activation level

360/720

360/720

360/720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B098

Thermistor for thermal protection

00

00

00

 

 

 

 

C

 

 

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B099

Thermal protection level setting

3000.

3000.

3000.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B100

Free-setting V/f frequency (1)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B101

Free-setting V/f voltage (1)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B102

Free-setting V/f frequency (2)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B103

Free-setting V/f voltage (2)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B104

Free-setting V/f frequency (3)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B105

Free-setting V/f voltage (3)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B106

Free-setting V/f frequency (4)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B107

Free-setting V/f voltage (4)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B108

Free-setting V/f frequency (5)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B109

Free-setting V/f voltage (5)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B110

Free-setting V/f frequency (6)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B111

Free-setting V/f voltage (6)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B112

Free-setting V/f frequency (7)

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B113

Free-setting V/f voltage (7)

0.0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B120

Brake Control Enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B121

Brake Wait Time for Release

0.00

0.00

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B122

Brake Wait Time for Acceleration

0.00

0.00

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B123

Brake Wait Time for Stopping

0.00

0.00

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B124

Brake Wait Time for Confirmation

0.00

0.00

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B125

Brake Release Frequency Setting

0.00

0.00

0.00