C–15

SJ300 Inverter

Expansion Card

Functions

 

 

“P” Group Parameters

 

Default Setting

 

User

 

 

 

 

 

 

 

 

 

 

Func.

 

 

 

 

 

 

 

Name

-FE (Europe)

-FU (U.S.)

-FR (Japan)

Setting

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P001

Operation mode on expansion card 1

00

00

00

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P002

Operation mode on expansion card 2

00

00

00

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P010

Feedback option enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

P011

Encoder pulse-per-revolution (PPR)

1024

1024

1024

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P012

Control pulse setting

00

00

00

 

 

 

 

 

 

 

 

 

 

 

CAppendix

 

P015

Home search speed setting

5.00

5.00

5.00

 

 

 

P013

Pulse line mode setting

00

00

00

 

 

 

 

P014

Home search stop position setting

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

P016

Home search direction setting

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

P017

Home search completion range

5

5

5

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P018

Home search completion delay time

0.00

0.00

0.00

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P019

Electronic gear set position selection

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

P020

Electronic gear ratio numerator

1.

1.

1.

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P021

Electronic gear ratio denominator

1.

1.

1.

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P022

Feed-forward gain setting

0.00

0.00

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

P023

Position loop gain setting

0.50

0.50

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

P025

Temperature compensation

00

00

00

 

 

 

 

 

thermistor enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P026

Over-speed error detection level

135.0

135.0

135.0

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P027

Speed deviation error detection level

7.50

7.50

7.50

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P031

Accel/decel time input selection

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

P032

Positioning command input selec-

00

00

00

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P044

DeviceNet comm watchdog timer

01

01

01

 

 

 

 

 

 

 

 

 

 

 

 

 

P045

Inverter action on DeviceNet comm

21

21

21

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P046

DeviceNet polled I/O: Output

71

71

71

 

 

 

 

 

instance number