3–68

Programming Error Codes

Programming Error Codes

Configuring Drive

Parameters

 

 

The SJ300 inverter operator keypad displays a special code (begins with the character) to indicate a programming error. Programming errors exist when one parameter conflicts with the meaningful range permitted by related parameter(s). Note that particular real-time frequency (speed) input levels can cause a conflict in some situations. After a conflict exists, the error code will appear on the display, or you can view it later with D090 in Monitor Mode. Also, the PGM LED on the display will flash ON/OFF when programming. These indications are automatically cleared when the parameter is corrected to the allowed range.

Programming ErrorParameter out of bounds

 

Boundary defined by...

 

 

 

 

 

Code

Code

Description

<, >

Code

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

001 201

A061 / A261

Frequency upper limit

>

A004 /

Maximum frequency;

 

 

setting; 1st, 2nd motor

 

A204 /

1st, 2nd, 3rd motor

 

 

 

 

A304

 

002 202

A062 / A262

Frequency lower limit

>

 

 

 

 

 

setting; 1st, 2nd motor

 

 

 

 

 

 

 

 

 

004 204 304

A003 / A203 /

Base frequency setting;

>

 

 

 

A303

1st, 2nd, 3rd motor

 

 

 

 

 

 

 

 

 

005 205 305

F001,

Output frequency setting,

>

 

 

 

A020 / A220 /

Multi-speed freq. setting;

 

 

 

 

A320

1st, 2nd, 3rd motor

 

 

 

 

 

 

 

 

 

006 206 306

A021 to A035

Multi-speed freq. settings

>

 

 

 

 

 

 

 

 

012 212

A062 / A262

Frequency lower limit

>

A061 / A261

Frequency upper limit setting;

 

 

setting; 1st, 2nd motor

 

 

1st, 2nd motor

 

 

 

 

 

 

015 215

F001,

Output frequency setting,

>

 

 

 

A020 / A220

Multi-speed freq. setting;

 

 

 

 

 

1st, 2nd motor

 

 

 

 

 

 

 

 

 

016 216

A021 to A035

Multi-speed freq. settings

>

 

 

 

 

 

 

 

 

021 221

A061 / A261

Frequency upper limit

<

A062 / A262

Frequency lower limit setting;

 

 

setting; 1st, 2nd motor

 

 

1st, 2nd motor

 

 

 

 

 

 

025 225

F001,

Output frequency setting,

<

 

 

 

A020 / A220

Multi-speed freq. setting;

 

 

 

 

 

1st, 2nd motor

 

 

 

 

 

 

 

 

 

031 231

A061 / A261

Frequency upper limit

<

B082

Start frequency adjustment

 

 

setting; 1st, 2nd motor

 

 

 

 

 

 

 

 

 

032 232

A062 / A262

Frequency lower limit

<

 

 

 

 

setting; 1st, 2nd motor

 

 

 

 

 

 

 

 

 

035 235 335

F001,

Output frequency setting,

<

 

 

 

A020 / A220 /

Multi-speed freq. setting;

 

 

 

 

A320

1st, 2nd, 3rd motor

 

 

 

 

 

 

 

 

 

036

A021 to A035

Multi-speed freq. settings

<

 

 

 

 

 

 

 

 

037

A038

Jog frequency setting

<

 

 

 

 

 

 

 

 

085 285 385

F001,

Output frequency setting,

>f-x,

A063 ± A064

Jump (center) frequency ±

 

A020 / A220 /

Multi-speed freq. setting;

<f+x

A065 ± A066

jump (hysteresis) frequency

 

A320

1st, 2nd, 3rd motor

 

A067 ± A068

width setting

 

 

 

 

 

 

086

A021 to A035

Multi-speed freq. settings

>f-x,

 

(See note after table)

 

 

 

<f+x