C–8

Parameter Settings for Keypad Entry

 

 

 

“B” Group Parameters

 

Default Setting

 

User

 

 

 

 

 

 

 

 

 

 

 

Func.

 

 

 

 

 

 

 

Name

-FE (Europe)

-FU (U.S.)

-FR (Japan)

Setting

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B023

Deceleration rate at overload restric-

1.0

1.0

1.0

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B024

Overload restriction operation mode

01

01

01

 

 

 

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B025

Overload restriction setting (2)

Rated current x

Rated current x

Rated current x

 

 

 

 

 

 

1.50

1.50

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

B026

Deceleration rate at overload

1.00

1.00

1.00

 

 

 

 

 

restriction (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B031

Software lock mode selection

01

01

01

 

 

 

 

 

 

 

 

 

 

 

 

 

B034

Run/power-on warning time

0.

0.

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

B035

Rotational direction restriction

00

00

00

 

 

Appendix

 

 

 

 

 

 

 

 

 

B036

Reduced voltage start selection

06

06

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B037

Function code display restriction

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B040

Torque limit selection

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B041

Torque limit (1) (forward-driving in

150.

150.

150.

 

 

 

 

 

 

 

 

4-quadrant mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B042

Torque limit (2) (reverse-regenerat-

150.

150.

150.

 

 

 

 

 

ing in 4-quadrant mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B043

Torque limit (3) (reverse-driving in

150.

150.

150.

 

 

 

 

 

4-quadrant mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B044

Torque limit (4) (forward-regenerat-

150.

150.

150.

 

 

 

 

 

ing in 4-quadrant mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B045

Torque limit LADSTOP enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B046

Reverse Run protection enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B050

Controller deceleration and stop on

00

00

00

 

 

 

 

 

power loss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B051

DC bus voltage trigger level during

0.0

0.0

0.0

 

 

 

 

 

power loss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B052

Over-voltage threshold during power

0.0

0.0

0.0

 

 

 

 

 

loss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B053

Deceleration time setting during

1.00

1.00

1.00

 

 

 

 

 

power loss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B054

Initial output frequency decrease

0.00

0.00

0.00

 

 

 

 

 

during power loss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B080

[AM] terminal analog meter adjust-

180

180

180

 

 

 

 

 

ment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B081

[FM] terminal analog meter adjust-

60

60

60

 

 

 

 

 

ment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B082

Start frequency adjustment

0.50

0.50

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

B083

Carrier frequency setting

5.0

5.0

5.0