vii

SJ300 Inverter

Warnings for Operations and Monitoring

WARNING: Be sure to turn ON the input power supply only after closing

............... 4–3

the front case. While the inverter is energized, be sure not to open the front

 

case. Otherwise, there is the danger of electric shock.

 

WARNING: Be sure not to operate electrical equipment with wet hands.

............... 4–3

Otherwise, there is the danger of electric shock.

 

WARNING: While the inverter is energized, be sure not to touch the

............... 4–3

inverter terminals even when the motor is stopped. Otherwise, there is the

 

danger of electric shock.

 

WARNING: If the Retry Mode is selected, the motor may suddenly restart

............... 4–3

after a trip stop. Be sure to stop the inverter before approaching the machine

 

(be sure to design the machine so that safety for personnel is secure even if

 

it restarts.) Otherwise, it may cause injury to personnel.

 

WARNING: If the power supply is cut OFF for a short period of time, the

............... 4–3

inverter may restart operation after the power supply recovers if the Run

 

command is active. If a restart may pose danger to personnel, so be sure to

 

use a lock-out circuit so that it will not restart after power recovery. Other-

 

wise, it may cause injury to personnel.

 

WARNING: The Stop Key is effective only when the Stop function is

............... 4–3

enabled. Be sure to enable the Stop Key separately from the emergency

 

stop. Otherwise, it may cause injury to personnel.

 

WARNING: During a trip event, if the alarm reset is applied and the Run

............... 4–3

command is present, the inverter will automatically restart. Be sure to apply

 

the alarm reset only after verifying the Run command is OFF. Otherwise, it

 

may cause injury to personnel.

 

WARNING: Be sure not to touch the inside of the energized inverter or to

............... 4–3

put any conductive object into it. Otherwise, there is a danger of electric

 

shock and/or fire.

 

WARNING: If power is turned ON when the Run command is already

............... 4–3

active, the motor will automatically start and injury may result. Before

 

turning ON the power, confirm that the RUN command is not present.

 

WARNING: When the Stop key function is disabled, pressing the Stop key

............... 4–3

does not stop the inverter, nor will it reset a trip alarm.

 

WARNING: Be sure to provide a separate, hard-wired emergency stop

............... 4–3

switch when the application warrants it.

 

WARNING: If the power is turned ON and the Run command is already

............. 4–12

active, the motor starts rotation and is dangerous! Before turning power ON,

 

confirm that the external Run command is not active.

 

WARNING: After the Reset command is given and the alarm reset occurs,

............. 4–27

the motor will restart suddenly if the Run command is already active. Be

 

sure to set the alarm reset after verifying that the Run command is OFF to

 

prevent injury to personnel.

 

WARNING: You may need to disconnect the load from the motor before

............. 4–67

performing auto-tuning. The inverter runs the motor forward and backward

 

for several seconds without regard to load movement limits.