C–13

SJ300 Inverter

Motor Constants

Functions

 

 

“H” Group Parameters

 

Default Setting

 

User

 

 

 

 

 

 

 

 

 

 

Func.

 

 

 

 

 

 

 

Name

-FE (Europe)

-FU (U.S.)

-FR (Japan)

Setting

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H001

Auto-tuning Setting

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

H002

Motor data selection, 1st motor

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

H202

Motor data selection, 2nd motor

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

H003

Motor capacity, 1st motor

Factory set

Factory set

Factory set

 

 

 

 

 

 

 

 

 

 

 

 

 

H203

Motor capacity, 2nd setting

Factory set

Factory set

Factory set

 

 

 

 

 

 

 

 

 

 

 

 

 

H004

Motor poles setting, 1st motor

4

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H204

Motor poles setting, 2nd motor

4

4

4

 

 

CAppendix

 

 

 

 

 

 

 

 

 

H006

Motor stabilization constant, 1st

100.

100.

100.

 

 

 

H005

Motor speed constant, 1st motor

1.590

1.590

1.590

 

 

 

 

H205

Motor speed constant, 2nd motor

1.590

1.590

1.590

 

 

 

 

 

motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H206

Motor stabilization constant, 2nd

100.

100.

100.

 

 

 

 

 

 

 

 

motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H306

Motor stabilization constant, 3rd

100.

100.

100.

 

 

 

 

 

motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H20

Motor constant R1, 1st motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H220

Motor constant R1, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H021

Motor constant R2, 1st motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H221

Motor constant R2, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H022

Motor constant L, 1st motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H222

Motor constant L, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H023

Motor constant Io

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H223

Motor constant Io, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H024

Motor Constant J

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H224

Motor constant J, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H030

Auto constant R1, 1st motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating

 

 

 

 

 

 

 

 

 

 

 

 

 

H230

Auto constant R1, 2nd motor

According to

According to

According to

 

 

 

 

 

 

inverter rating

inverter rating

inverter rating