1–8

SJ300 Inverter Specifications

Tables for 400V class inverters, continued...

Started

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

400V Class Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Geting

 

SJ300 inverters,

 

U.S. version

 

750HFU

900HFU

1100HFU

1500HFU

 

400V models

 

 

 

 

 

 

 

 

 

 

 

 

European ver.

750HFE

900HFE

1100HFE

1320HFE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicable motor size

*2

 

HP

100

125

150

175

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

75

90

110

132

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated capacity (400 / 480V) kVA

 

103.2 / 123.8

121.9 / 146.3

150.3 / 180.4

180.1 / 216.1

180.1 / 216.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated input voltage

 

 

 

 

 

3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%

 

 

 

 

 

 

 

 

 

 

 

 

Rated input current (A)

 

164

194

239

286

286

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated output voltage

*3

 

 

3-phase (3-wire): 380 to 480V (corresponding to input voltage)

 

 

 

 

 

 

 

 

 

 

 

Rated output current (A)

 

149

176

217

260

260

 

 

 

 

 

 

 

 

 

 

 

Efficiency at 100% rated output, %

 

95.2

95.2

95.2

95.2

95.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Watt loss,

 

at 70% output

2675

3375

3900

4670

4670

 

 

approximate (W)

 

 

 

 

 

 

 

 

 

 

 

 

at 100% output

3800

4800

5550

6650

6650

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting torque *6

 

 

 

 

180% at 0.5 Hz (SLV), 130% at around 0 Hz (SLV, 0 Hz domain,

 

 

 

 

 

 

 

with motor one frame size down), 100% at 0 Hz (with feedback board)

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic braking

 

w/o braking unit

 

 

10%

 

 

 

 

approx. % torque,

 

 

 

 

 

 

 

 

 

 

 

 

with braking unit

45–70%

40–60%

30–50%

25–40%

20–35%

 

 

short time stop *7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking

 

 

 

 

 

Variable operating frequency, time, and braking force

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

kg / lb

 

60 / 132

60 / 132

80 / 176

80 / 176

80 / 176

 

 

 

 

 

 

 

 

 

 

 

 

Footnotes for the preceding tables and the table that follows:

Note 1: The protection method conforms to JEM 1030.

Note 2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using other motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the rated output current of the inverter.

Note 3: The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.

Note 4: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the maximum allowable rotation speed.

Note 5: When SLV is selected, please set the carrier frequency higher than 2.1 kHz.

Note 6: At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor (when selecting sensorless vector control—SLV).

Note 7: The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking torque. The average decel torque varies with motor loss. This value decreases when operating beyond 50 Hz. If a large regenerative torque is required, the optional regenerative braking resistor should be used.

Note 8: The frequency command will equal the maximum frequency at 9.8V for input voltage 0 to 10 VDC, or at 19.6 mA for input current 4 to 20 mA. If this characteristic is not satisfactory for your application, contact your Hitachi sales representative.

Note 9: The storage temperature refers to the short-term temperature during transport.

Note 10: Conforms to the test method specified in JIS C0911 (1984). For the model types excluded in the standard specifications, contact your Hitachi sales representative.

Note 11: NEMA 1 applies up to 22kW. An optional wire-entry conduit box is required for 30kW to 55kW models to meet NEMA 1 rating.