Service Calibrations

following message will be displayed while the Printer measures the pattern:

ACCURACY

Measuring

8Once the calibration is completed, the following message will be displayed:

 

 

 

 

 

Top

 

 

 

 

 

 

 

Back

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibration done

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press ENTER to continue

 

 

 

 

Press Enter

 

 

 

 

 

 

 

 

 

Enter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9To check if the Calibration was completed correctly, print the Service Configuration Print (see Page 1-19) and check that the values given for the Accuracy Calibration are NOT ALL zero.

Check that these value are NOT ALL zero

10If the calibration fails Perform the Electronic Systems Test Page 4-5.

5-8

HP DesignJets 1050C and 1055CM Printers Service Manual