System Error Codes
|
|
| System Error Codes During Initialization |
|
|
| The following System Error Codes will only appear during the |
|
|
| Initialization process when you power ON the Printer. |
|
|
|
|
System Error: | 0B0000 | ||
Problem | Bad Ambient Temperature measured. | ||
Description: |
| ||
Corrective Action: | Try the following: | ||
|
|
| n Make sure that the Ambient temperature is within the allowed |
|
|
| range (between 0 and 55 Degrees Centigrade). |
|
|
| n Replace the Electronics Module ⇒ Page |
|
|
|
|
System Error: | 0B0001 | ||
Problem | Bad Humidity read. | ||
Description: |
| ||
Corrective Action: | Replace the Electronics Module ⇒ Page | ||
|
|
|
|
System Error: | 0B0002 | ||
Problem | Bad IDS pressure read. | ||
Description: |
| ||
Corrective Action: | Try the following: | ||
|
|
| n Check that the cable from the Ink Supply Station (ISS) PCA to |
|
|
| the Ink Supply Station is correctly connected. |
|
|
| n Check that the Air Pressurization System Sensor Cable is |
|
|
| correctly connected and is NOT damaged. |
|
|
| n Check all the tubes of the APS and make sure they are NOT |
|
|
| pinched or damaged. |
|
|
| n Faulty APS Sensor. Replace the complete APS ⇒ Page |
|
|
| n If the error code continues, replace the Electronics Module ⇒ |
|
|
| Page |
|
| Only replace one component at a time and check if the error has | |
WARNING | |||
|
|
| gone before replacing another component. Using this procedure |
|
|
| you will be able to determine exactly which component failed. |
|
|
|
|
HP DesignJets 1050C and 1055CM Printers Service Manual |