Service Calibrations

 

 

 

7. Calibrations Backup

 

The purpose of this Service Calibration is to allow the EEROM

 

contents to be saved when the Electronics Module or the Tubes

 

System has been replaced.

 

ALWAYS PERFORM THE CALIBRATIONS BACKUP

WARNING

 

AFTER REPLACING THE ELECTRONICS MODULE OR

 

THE TUBES SYSTEM.

 

 

Perform the Calibrations Backup as follows:

1In the Service Utilities submenu, scroll to "7. Calibrations Backup" and press Enter.

Service Calibrations

4.Roller mark position...

5.Pen to Paper Spacing...

6.Color to Color cal...

7.Calibrations backup...

8.Pen Alignment...

Top

 

 

 

 

Back

 

 

 

 

 

 

 

Make Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

Press Enter

 

 

 

 

Enter

 

 

 

 

 

 

2When the following message appears on the front panel, you must select which component you have replaced. Select either the Electronics Module or Tubes System and press Enter.

 

 

 

 

 

 

 

Top

 

 

 

 

 

CALIBRATIONS BACKUP

 

 

 

Back

 

 

 

 

 

 

What have you

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replaced?

 

 

 

 

 

 

Make Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronics Module repl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tubes replaced...

 

 

 

 

 

 

 

Press Enter

 

 

 

 

 

Enter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the Electronics Module was replaced

aIf the Electronics Module was replaced, then select Electronics Module and press Enter.

 

 

 

 

 

 

 

Top

 

 

 

 

 

CALIBRATIONS BACKUP

 

 

 

Back

 

 

 

 

 

 

What have you

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replaced?

 

 

 

 

 

 

Make Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronics Module repl

 

 

 

 

 

 

 

 

 

Tubes replaced...

 

 

 

 

 

 

 

Press Enter

 

 

 

 

 

Enter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bThe following message will appear asking you to confirm the operation. Select ACCEPT if you want to continue the Calibrations Backup, or select

HP DesignJets 1050C and 1055CM Printers Service Manual

5-19