System Error Codes

System Error:

0A0000

Problem

The Air Pressure is below the minimum requirement.

Description:

 

Corrective Action:

Try the following:

WARNING

System Error:

Problem

Description:

Corrective Action:

nCheck all the cables of the APS and make sure they are correctly connected and are NOT damaged.

nCheck all the tubes of the APS and Tubes System and make sure they are correctly connected and are NOT pinched or damaged.

nCheck that the Air Tube from the APS is correctly connected to the Tubes System.

nFaulty APS Sensor, APS Valve or APS Pump. Replace the complete APS Page 8-20.

nReplace ONE Ink Cartridge at a time, checking if the error code disappears.

Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.

0A0010

Problem in Pressurizing the Air System.

Try the following:

n Replace ONE Ink Cartridge at a time, checking if the error code disappears.

n Check all the cables of the APS and make sure they are correctly

 

connected and are NOT damaged.

 

n Check all the tubes of the APS and Tubes System and make sure

 

they are correctly connected and are NOT pinched or damaged.

 

n Faulty APS Sensor, APS Valve or APS Pump. Replace the

 

complete APS Page 8-20.

 

Only replace one component at a time and check if the error has

WARNING

 

gone before replacing another component. Using this procedure

 

you will be able to determine exactly which component failed.

 

 