System Error Codes

System Error:

0A0050 (Non-Continuable)

Problem

The Printer has detected a leak in the Tubes System before the life

Description:

of the System.

Corrective Action:

Try the following:

WARNING

System Error:

Problem

Description:

Corrective Action:

nThe leak detector could have been triggered due to condensation in the Printer. Power OFF the Printer and allow the Printer to dry for 15 minutes. Power ON the Printer and check if the error code has disappeared.

nIf the Error Code reappears, replace the complete Tubes System (SRK) Page 8-53.

Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.

0A0060 (Non-Continuable)

The Printer has detected a leak in the Tubes System after the life of the System.

Try the following:

n The leak detector could have been triggered due to condensation

 

in the Printer. Power OFF the Printer and allow the Printer to dry

 

for 15 minutes. Power ON the Printer and check if the error code

 

has disappeared.

 

n If the error code reappears, replace the complete Tubes System

 

(SRK) Page 8-53.

 

Only replace one component at a time and check if the error has

WARNING

 

gone before replacing another component. Using this procedure

 

you will be able to determine exactly which component failed.

 

 

HP DesignJets 1050C and 1055CM Printers Service Manual

2-15