Table 56 About the Monitoring Options (continued)

Available

Available to Which Elements

Description

Monitoring

 

 

 

Options

 

 

 

 

 

 

 

Bytes Received

Storage systems

Number of bytes received by the port per

(MB/Sec)

Host (port for HBA card)

second

 

NAS filer (IP port)

 

 

Switch port

 

 

 

 

CPU Usage

Sybase

Percentage of the Sybase CPU being

Percentage (%)

 

 

used. For example, if this monitoring

 

 

 

appears pegged at 100 percent, this

 

 

 

means one or more Sybase databases on

 

 

 

the host (not the host CPU) are using 100

 

 

 

percent of the Sybase CPU. The host CPU

 

 

 

could be pegged at 60 percent, while

 

 

 

the Sybase CPU is pegged at 100

 

 

 

percent.

 

 

 

 

CRC Errors

Storage systems

The number of cyclic redundancy check

(Errors/Sec)

Host (port for HBA card)

(CRC) errors per second.

 

Switch port

 

 

 

 

Data Received

NAS filers

The data received per second by an IP

(rate/sec)

 

 

port on a filer.

 

 

 

Data Sent

NAS filers

The data sent per second by an IP port

(rate/sec)

 

 

on a filer.

 

 

 

Dictionary Hit

Oracle

The ratio you use to determine if the

Ratio

 

 

shared pool is large enough to store

 

 

 

dictionary cache data adequately. If the

 

 

 

ratio is less then 95 percent, investigate

 

 

 

further. You may need to increase

 

 

 

shared_pool_size.

HP Storage Essentials SRM 6.0 User Guide 403