8.To modify the time-out period, set the corresponding property for your switch in the following table to the number of millisecond you want. The default is 5000 ms. For example, to change the time-out period to 30000 ms for a McDATA switch, you would set the cimom.McData.Snmp.Timeout property to 30000, as shown in the following example:

cimom.McData.Snmp.Timeout=30000

Table 159 Time-out Properties

Switch

Property

 

 

McDATA/Connectrix

cimom.McData.Snmp.Timeout

discovered through SNMP

 

 

 

Cisco

cimom.Cisco.Snmp.Timeout

Other switches discovered

cimom.snmp.switch.timeout

through SNMP:

 

Sun StorEdge

 

QLogic

 

 

 

 

1.To modify the number of retries, repeat steps 4 through 6 by copying and pasting the property specified in the table below. Set the corresponding property for your switch in the following table to the number of retries you want. The default is two retries. For example, to change the number of retries to five for a McDATA switch, set the cimom.McData.Snmp.Retries properties as shown in the following example:

cimom.McData.Snmp.Retries=5

Table 160 Retry Properties

Switch

Property

 

 

McDATA/Connectrix

cimom.McData.Snmp.Retries

discovered through SNMP

 

Cisco

cimom.Cisco.Snmp.Retries

Other switches discovered

cimom.snmp.switch.retries

through SNMP:

 

Sun StorEdge

 

QLogic

 

 

 

 

1.When you are done, click Save.

HP Storage Essentials SRM 6.0 User Guide 705