During the recalculation period, you may not be able to log into the application. If you are already logged into the application, navigation may not be possible until the topology recalculation is complete.

Troubleshooting the Java Plug-in

This section contains the following topics:

Java Applet Has Data from a Different Build of Management Server Software, page 720

OutOfMemoryException Messages, page 720

Improving Reload Performance in System Manager, page 720

Java Applet Has Data from a Different Build of Management Server Software

If you attempt to monitor a host with old JAR (Java Archive) files, you might be unable to monitor the host, and you might see the following error message:

The Java applet has data from a different version of the management server. Please close and re-start your browser.

The reason for this error message is that the client still has JARs from the previous build in its Java Plug-in cache. To remove the old JARs, clear the cache for the Java plug-in.

OutOfMemoryException Messages

In some rare cases it may be necessary to increase the amount of memory for the Java plug-in on the client computer. This should only be done if you are seeing OutOfMemoryException messages in the Java console on the client side.

Improving Reload Performance in System Manager

If your Java plug-in control panel cache is set at 50 MB, it is recommended you increase this setting to 150 MB or more. Increasing this setting improves the reloading performance of System Manager.

Troubleshooting Provisioning

This section contains the following topics:

Cannot Access a Resource Owned by Another Controller, page 720

Error -56, page 720

“Can't delete this zone” Message, page 721

Changes in EFC Manager Requiring Discovery Data Collection, page 721

Cannot Access a Resource Owned by Another Controller

If you receive a message about not being able to access a resource owned by another controller, it is because you tried to access a controller that has not been discovered. You should discover all controllers on the LSI storage system.

For example, assume you discovered only one of the controllers on an LSI storage system with two controllers. If you want to change a volume, such as add or delete a LUN, you will not be able to make the change to the volume associated with the controller that has not been discovered.

720 Troubleshooting