Table 162 Known Device Issues (continued)

Device

Software

Description

 

 

 

IBM Storage

Subsystem

If you discover an IBM storage system without SDD, incorrect

Systems

Device Driver

stitching is displayed in System Manager for the storage

 

(SDD) or MPIO

system. You are shown only one path if the storage system is

 

(multipath I/O)

using MPIO instead of SDD.

 

 

 

“mailbox command 17 failure status FFF7” Message

If one or more of your Microsoft Windows hosts are using an Emulex HBA driver, you may see the following message in Windows Event Viewer:

mailbox command 17 failure status FFF7

This message can be safely ignored. The HBAAPI is being used to access data in the flash memory of the adapter that does not exist, and this is causing the event to be logged. This issue has been seen with version 5.2.2 of the driver.

”Process Has an Exclusive Lock” Message

You will receive a message resembling the one shown below, if a process has already locked the EMC Symmetrix storage system, and you attempt a process that requires a lock on the Symmetrix storage system.

SYMAPI routine SymDevMaskSessionStart failed with error code 188: The operation failed because another process has an exclusive lock on the local Symmetrix.

The Symmetrix storage system can become locked for many reasons. For example, the storage system becomes locked when it performs LUN mapping, LUN masking, or Discovery Data Collection. The Symmetrix storage system may also remain locked after a provisioning operation has failed.

After the management server has detected the lock on the Symmetrix storage system, it tries to access the storage system for 15 minutes and then logs the errors.

If you receive the error message, determine if someone is performing an operation that requires a lock, such as LUN mapping, LUN masking, or Discovery Data Collection. This also applies even if one of the processes is being used by a third-party product, such as for LUN masking. If so, wait until the process is complete before you remove the lock manually. Be sure that no other processes are occurring on the storage system. To learn how to remove the lock, see the documentation for the Symmetrix storage system.

726 Troubleshooting