Issues Specific to CLARiiON Storage Systems
The following issues are specific to CLARiiON® storage systems:
•Making the Management Server a Privileged User for CLARiiON, page 564
•EMC Navisphere CLI Is Required, page 564
Making the Management Server a Privileged User for CLARiiON
Before you can provision a CLARiiON storage system, you must configure it to recognize the management server as a privileged user. This task can be completed by using NaviCli as follows:
C:\>navicli
where
•192.168.1.249 is the URL of the CLARiiON storage system
•SYSTEM@hostname is the name of the computer running the management server
•This example tells the CLARiiON storage system at 192.168.1.249 to accept configuration change requests from management server running on the computer named hostname.
EMC Navisphere CLI Is Required
The EMC Navisphere® CLI is required for the management server to communicate with the CLARiiON® storage system. At the time this documentation was created, EMC distributed the Navisphere CLI as part of the EMC Navisphere Software Suite. Contact your EMC representative for more information about obtaining the Navisphere CLI. Distribution rights for the Navisphere CLI belong to EMC. EMC Navisphere CLI Is Required
For the management server on Windows, use Navisphere Manager to add one of the following to the privilege user section:
SYSTEM@name_of_my_management_server
SYSTEM@IP_of_my_management_server
where
•name_of_my_management_server is the DNS name of the computer running the management server software
•IP_of_my_management_server is the IP address of the computer running the management server software
For the management server on UNIX systems, add the following to the privilege user section:
SYSTEM@root
When you discover the CLARiiON storage system, provide its IP address and the user name and password to be used to log into Navisphere.
Issues Specific to EMC Symmetrix Storage Systems
The following issues are specific to EMC Symmetrix Storage Systems:
•About Provisioning on EMC Symmetrix Storage Systems, page 565
•Process Has an Exclusive Lock Message, page 565
•Some EMC Volumes, Their LUNs and LUN Maskings Are Hidden, page 565