If you selected No in the Brocade SMI Agent Enabling Security window, you can enter any username and password because security for the proxy server was not enabled.

For Brocade SMI Agent installed on Linux or Solaris, see the Brocade SMI Agent documentation for more information about SMI Agent security for Linux or Solaris.

Discovering CNT Switches

The management server uses the CNT SMI-S provider to discover CNT switches. This provider communicates with CNT InVsn Enterprise Manager to obtain information about the switch. The provider requires a certain version of InVsn, depending on the switch model. See the support matrix for the required InVSN version for your switch model.

IMPORTANT: The InVsn credentials are used by the SMI-S provider. Make sure the SMI-S provider is enabled as described in the discovery process for CNT Switches.

When discovering CNT switches, note the following:

SNMP is not supported for CNT switches.

CNT InVsn Enterprise Manager must be running for the management server to discover it.

The management server does not support provisioning for CNT switches. Only the active zone set and its zone members are reported.

No ports are reported for uninstalled blades or Gigabit Interface Converters (GBICs).

Discovery Process for CNT Switches

To discover CNT switches:

1.Discover the host running the InVSN software.

a.Select Options > Discovery to open the HP SIM Automatic Discovery page.

b.Click New on the HP SIM Discovery page Automatic tab.

c.Enter a name for the discovery task in the Name box.

d.Clear the Automatically execute discovery every check box.

e.Enter the IP address of the host running the InVSN software in the Ping inclusion ranges, system (hosts) names, templates, and/or hosts files box.

f.Select the discovery task and click Run Now.

HP SIM pings the host. If the ping is successful, the element is added to HP SIM’s All Systems collection.

g.Select Options > Protocol Settings > System Protocol Settings and select the host you discovered as a target and provide the port number for the host in the WBEM section.

2.Take the following steps in the CNT InVsn Enterprise Manager software:

a.Open the file ProductInfo.ini in a text editor, such as Notepad. If the software was installed in the default directory, this file should be in the following directory:

\Program Files\CNT\inVSN_EM

34 Discovering Switches, Storage Systems, NAS Devices, and Tape Libraries