Problem Determination and Maintenance

Symptom/Action Chart

Symptom

Recommended Action

 

 

 

1. Ensure that the Power switch is switched on.

 

2. Be sure the power cord is securely connected to the display

 

station.

The Power–On indicator

Visually inspect the power cord for signs of damage.

stays off.

3. Be sure the power cord is plugged into an operational AC

 

outlet.

 

4. If the symptom persists, the Display/Logic element has

 

probably failed.

 

 

The Audible Alarm

Switch off the display station power, then switch the power

continuously sounds (will not

back on. If the symptom persists, the Display/Logic element

shut off).

has probably failed.

 

 

3 appears in the

1. Refer to “Electronic Security Lock” on Page 4–18.

operator status row

2. If the symptom persists, the Display/Logic element has

(display screen blank).

probably failed.

 

 

The Control Unit Ready

 

symbol, (6, 4, , i, or S), does

Ensure that the coax cable is securely connected to both an

not appear in the operator

operational control unit and the display station.

status row.

 

 

 

The screen is completely

Adjust the Contrast and/or Brightness controls. If the screen still

remains dark, replace the Display/Logic element. If the problem

dark and pressing the space

recurs or your screen needs frequent contrast adjustments,

bar does nothing.

replace the Display/Logic element.

 

 

 

The screen is not displaying

Adjust the vertical refresh rate (color displays) or the

correctly, or is flickering, or is

mode/intensity setting (monochrome displays). See Page 4-2 for

receiving interference from

instructions.

nearby devices

 

 

 

 

If the screen exhibits any of the following problems

 

1. Nothing displayed (no operator status row).

 

2. Display area drifts horizontally or vertically.

 

3. Characters fuzzy, out of focus.

 

4. Display area is noticeably reduced or expanded.

The screen is distorted.

5. Display are is tilted.

6. Abnormal sound or odor.

 

 

7. Characters have extra or missing dots.

 

Set the Power switch to Off ( O ). While holding down the space

 

bar, set the Power switch to On ( ). Hold down the space bar

 

until the Offline Test menu appears. If the menu does not display

 

as described in Chapter 3, replace the Display/Logic element.

 

 

Monitor display problems

Set Dim Style to Status Row Only, Refer to “Dim Style” on

during Auto-screen cutoff.

Page 3-23.

 

 

7-12

701344-003

Page 110
Image 110
IBM 1483DSV manual Symptom/Action Chart, Symptom Recommended Action