Universal Asynchronous Receiver Transceiver (UART)—Intel® IXP42X product line and IXC1100
control plane processors
10.5.1.11 Modem Status Register

This register provides the processor with the current state of the control lines from the

modem or data set (or a peripheral device emulating a modem). In addition to this

current state information, four bits of the Modem Status Register provide change

information.

These bits — 3:0 — are set to a logic 1 when a control input from the modem changes

state. They are reset to a logic 0 when the processor writes ones to the bits of the

Modem Status Register.

Note: When bits 0, 1, 2, or 3 are set to logic 1, a Modem Status Interrupt is generated — if bit

3 of the Interrupt Enable Register is set.

2PE
Parity Error: PE indicates that the received data character does not have the
correct even or odd parity, as selected by the even parity select bit. The PE is
set to logic 1 upon detection of a parity error and is reset to logic 0 when the
processor reads the Line Status register.
In FIFO mode, PE shows a parity error for the character at the bottom of the
FIFO, not the most recently received character.
1OE
Overrun Error: In non-FIFO mode, OE indicates that the processor did not
read data the receiver buffer register before the next character was received.
The new character is lost.
In FIFO mode, OE indicates that all 64 bytes of the FIFO are full and the most
recently received byte has been discarded. The OE indicator is set to logic 1
upon detection of an overrun condition and reset when the processor reads the
Line Status register.
0DR
Data Ready: Bit 0 is set to logic 1 when a complete incoming character has
been received and transferred into the receiver buffer register or the FIFO.
In non-FIFO mode, DR is reset to 0 when the receive buffer is read. In FIFO
mode, DR is reset to a logic 0 if the FIFO is empty (last character has been read
from RBR) or the RESETRF bit is set in the FCR.
0 = No data has been received
1 = Data is available in RBR or the FIFO
Register LSR (Sheet 2 of 2)
Bits Name Description
Register Name: MSR
Hex Offset Address: 0xC800 1018 Reset Hex Value: 0x00000000
Register
Description: Modem Status Register
Access: Read Only.
31 876543210
(Reserved)
DCD
RI
DSR
CTS
DDCD
TERI
DDSR
DCTS