Intel SBCEGBESW1 manual Show rmon alarm-table, Following example displays the alarms table

Models: SBCEGBESW10 CLI SBCEGBESW1

1 424
Download 424 pages 57.83 Kb
Page 224
Image 224

RMON Commands

show rmon alarm-table

The show rmon alarm-tablePrivileged EXEC mode command displays the alarms table.

Syntax

show rmon alarm-table

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the alarms table.

Console# show rmon alarm-table

Index

OID

Owner

-----

----------------------

-------

1

1.3.6.1.2.1.2.2.1.10.1

CLI

2

1.3.6.1.2.1.2.2.1.10.1

Manager

3

1.3.6.1.2.1.2.2.1.10.9

CLI

The following table describes significant fields shown in the example:

Field

Description

 

 

Index

An index that uniquely identifies the entry.

 

 

OID

Monitored variable OID.

 

 

Owner

The entity that configured this entry.

 

 

208Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide