Intel SBCEGBESW10 CLI manual Dot1x timeout quiet-period, Quiet period is 60 seconds

Models: SBCEGBESW10 CLI SBCEGBESW1

1 424
Download 424 pages 57.83 Kb
Page 404
Image 404

802.1x Commands

Command Mode

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following command manually initiates a re-authentication of 802.1x-enabled Ethernet port 16.

Console# dot1x re-authenticate ethernet ext.16

dot1x timeout quiet-period

The dot1x timeout quiet-periodInterface Configuration mode command sets the number of seconds that the device remains in the quiet state following a failed authentication exchange (for example, the client provided an invalid password). To return to the default configuration, use the no form of this command.

Syntax

dot1x timeout quiet-period seconds no dot1x timeout quiet-period

Parameters

seconds — Specifies the time in seconds that the device remains in the quiet state following a failed authentication exchange with the client. (Range: 0-65535 seconds)

Default Configuration

Quiet period is 60 seconds.

Command Mode

Interface Configuration (Ethernet) mode

User Guidelines

During the quiet period, the device does not accept or initiate authentication requests.

388Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide

Page 404
Image 404
Intel SBCEGBESW1 Dot1x timeout quiet-period, Quiet period is 60 seconds, Console# dot1x re-authenticate ethernet ext.16