Intel SBCEGBESW10 CLI Show radius-servers, Following example displays Radius server settings

Models: SBCEGBESW10 CLI SBCEGBESW1

1 424
Download 424 pages 57.83 Kb
Page 237
Image 237

RADIUS Commands

Syntax

show radius-servers

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays RADIUS server settings.

Console# show radius-servers

IP address

Port

TimeOut

Retransmit

DeadTime

Source IP

Priority

Usage

 

Auth

 

 

 

 

 

 

---------

----

-------

----------

------

--------

--------

-----

172.16.1.1

1645

Global

Global

Global

-

1

All

172.16.1.2

1645

11

8

Global

Global

2

All

Global values

 

 

 

 

 

 

 

-------------

 

 

 

 

 

 

 

TimeOut: 3

 

 

 

 

 

 

 

Retransmit: 3

 

 

 

 

 

 

 

Deadtime: 0

 

 

 

 

 

 

 

Source IP: 172.16.8.1

Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide

221

Page 237
Image 237
Intel SBCEGBESW10 CLI Show radius-servers, Following example displays Radius server settings, Console# show radius-servers