Configuration and Image File Commands

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

The location of a file system dictates the format of the source or destination URL.

The entire copying process may take several minutes and differs from protocol to protocol and from network to network.

*.prv and *.sys files cannot be copied.

Understanding Invalid Combinations of Source and Destination

Some invalid combinations of source and destination exist. Specifically, you cannot copy if one of the following conditions exist:

The source file and destination file are the same file.

xmodem: is the destination file. The source file can be copied to image, boot and null: only.

tftp:// is the source file and destination file on the same copy. The following table describes copy characters:

Character

Description

 

 

!

For network transfers, indicates that the copy process is taking place. Each exclamation

 

point indicates successful transfer of ten packets (512 bytes each).

 

 

.

For network transfers, indicates that the copy process timed out. Generally, many

 

periods in a row means that the copy process may fail.

 

 

Copying an Image File from a Server to Flash Memory

To copy an image file from a server to flash memory, use the copy source-urlimage command.

Copying a Boot File from a Server to Flash Memory

To copy a boot file from a server to flash memory, enter the copy source-urlboot command.

Copying a Configuration File from a Server to the Running Configuration File