Administering the Switch for CMS High Availability Systems
CentreVu
CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Administering the Definity Switch 4-8
Adding a Second
Packet Interface 4
This procedure is required only for
Definity
G3csi switches.
Use the Maintenance-Related System Parameters form to add a second
packet interface to the G3csi switch. This is required for CMS computer
connectivity.
change system-parameter maintenance Page 2 of X
MAINTENANCE-RELATED SYSTEM PARAMETERS
MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )
TTRs: 4 CPTRs: 1 Call Classifier Ports:
MMIs: 0 VCs:
TERMINATING TRUNK TRANSMISSION TEST (Extension)
Test Type 100: Test Type 102: Test Type 105:
ISDN MAINTENANCE
ISDN-PRI TEST CALL Extension: ISDN BRI Service SPID:
DS1 MAINTENANCE
DSO Loop-Around Test Call Extension:
LOSS PLAN (Leave Blank if no Extra Loss is Required)
Minimum Number of Parties in a Conference Before Adding Extra Loss:
SPE OPTIONAL BOARDS
Packet Intf1? y Packet Intf2? y
Bus Bridge: 01A03 Inter-Board Link Timeslots Pt0: 6 Pt1: 1 Pt2: 1