Upgrading CMS to the High Availability Option

CentreVu

CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Setting Up the Alarm Originator 3-59
8. Enter y. The system automatically reboots and the remote console
port comes up as a regular dial-in port with the login: prompt
displayed.
As the system reboots, the shutting-down messages appears on the
remote console. When the system starts to come back up, the
system boot diagnostics should appear on the local console. After
the system reboots, a login prompt should appear on the local
console.
9. Log into the local console as

root

.
The console has been redirected from the remote console to the
local console.
Setting Up the Alarm Originator 3
For information on setting up the alarm origination manager on the HA
servers, see “CentreVu CMS R3V8 Alarm Origination Manager (585-215-
884).
Setting Up the NTS C
For information about setting up the NTS, see “Setting up the NTS”, in
Chapter 2 of “CentreVu Call Management System R3V8 Software
Installation and Setup” (585-210-941).

Configuring the

NTS 3
This procedure is performed on NTS devices when:
the NTS is newly installed, or
the NTS requires reconfiguration during a manual HA server switch-
over after the HA server to which the NTS was initially connected
has experienced a failure event
1. Connect a dumb terminal to the Console Port on the rear of the NTS
using the console cable and adapter that came with the NTS. On
the 8- and 16-port NTSs, the Console Port is port #1.
You will need the following for the 8- and 16-port units:
Console Cable
Adapter - comcode 407361823
Null Modem - comcode 407122043.