Upgrading CMS to the High Availability Option

CentreVu CMS R3V8 High Availability

 

 

 

 

Connectivity, Upgrade and Administration

 

Setting Up CMS on an HA Server

3-21

 

 

 

 

 

 

 

 

 

 

 

Setting Up Data

Storage

Parameters

Overview

Procedure

TSC personnel modify specific data storage parameters on the CMS computer so that the CMS application can operate properly. The storage.def file contains these data storage parameters, which are installed with a set of standard default values.

Review the default data storage values for each authorized ACD. The default values are found on the line immediately below each storage parameter, and many of them can be can be edited to meet the needs of individual customers. Use the values determined by the Account Executive, System Consultant, and Design Center based on the customer configuration. For a new HA system being added to an existing CMS installation, these values should be identical to the values installed on the original server at the customer site.

1.To change to the CMS installation directory, enter: cd /cms/install/cms_install

2.Enter:

vi storage.def

NOTE:

If you delete or damage the storage.def file, you can find a copy of this file (storage.skl) in the same directory.

3.The default storage parameters are listed (immediately below each of the defined storage paremeters) in the order in which they appear in the storage.def file.

# Intrahour interval (15, 30, 60 minutes): 30

# Week start day (Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday):

Sunday

# Week end day (Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday):

Saturday