Upgrading CMS to the High Availability Option  | CentreVu CMS R3V8 High Availability  | 
  | |
  | 
  | Connectivity, Upgrade and Administration  | 
  | 
Setting Up CMS on an HA Server | 
  | ||
  | 
  | 
  | 
  | 
17.Enter the remote port or channel number on the switch.
You must now select how the CMS platform is connected to the Definity switch for message transport. The program responds:
Select the transport to the switch
1)X.25
2)TCP/IP
Enter choice 
Enter 2 to select TCP/IP.
18. The program responds:
Enter Definity ECS host name or IP Address:
19.Enter the host name of the Definity ECS (not the IP address) that is connected to this ACD. If you enter a host name that has not been added to the computer’s /etc/hosts file, the program responds:
Switch_name has not been administered in a DNS or /etc/hosts file. The DNS or /etc/hosts file must be corrected or the link to the switch will not work.
See the switch LAN setup on “Editing the /etc/hosts File” on Page 3- 25 for more information about setting up the hosts file. The program continues:
Enter Definity ECS TCP port number 
(default: 5001)
20.Press Enter to use the default TCP port number 5001. This number must match the port number administered on the Definity switch.
The program responds:
Number of splits/skills