Windows Setup and Operation 3-47

3.Stop the operation of a PCI module using the ft server utility.

Select [Start] - [All Programs] - [NEC ESMPRO Agent] - [ft server utility] to start the ft server utility.

Then, from the ft server utility, select [PCI Module] then the primary PCI module from the [FTSever] tree on the left pane, and click [Down] of [Bring Up/Bring Down]. When you stop the operation of the primary PCI module, a failover occurs and the secondary PCI module becomes the primary module.

The following events or changes occur when stopping the primary PCI module and the module fails over:

The screen temporarily blacks out and then displayed again. The following message will appear from the taskbar:

Windows - FT Orphaning: A disk that is part of a fault-tolerant volume can no longer be accessed.

* The message denotes that the mirror volumes of the hard disk stored in the disconnected PCI module are released.

* The message will not appear if disks are duplicated by the RDR function. Indications of PCI modules’ status LEDs change as follows:

[Indications of status LEDs]

 

LED

Secondary*

Primary*

1

BMC status LED

-

Green and blinking

2

PCI module status LED1

Red

-

3

PCI module status LED2

-

Amber

4

DISK ACCESS LED

-

Amber

DISK LED

-

Amber

* The primary and secondary modules after failover

4. Restart the PCI module.