| Troubleshooting | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Indication | STATUS LED | Suspected | Explanation | Procedure |
| |
Color | State | module |
| |||
|
|
|
| |||
CPU0 +5.0vAlm | Amber | Blink | CPU module #1 | Contact your sales agent. |
| |
07 |
|
|
| (upper limit) |
|
|
CPU0 +5.0vAlm | Amber | Lit | CPU module #1 | Fatal |
|
|
09 |
|
|
| (upper limit) |
|
|
CPU0 +5.0vsAlm | Amber | Blink | CPU module #1 |
|
| |
00 |
|
|
| (lower limit) |
|
|
CPU0 +5.0vsAlm | Amber | Lit | CPU module #1 | Fatal |
|
|
02 |
|
|
| (lower limit) |
|
|
CPU0 +5.0vsAlm | Amber | Blink | CPU module #1 |
|
| |
07 |
|
|
| (upper limit) |
|
|
CPU0 +5.0vsAlm | Amber | Lit | CPU module #1 | Fatal |
|
|
09 |
|
|
| (upper limit) |
|
|
CPU0 broken | Green | Blink | CPU module #1 | CPU module breakdown |
|
|
CPU0 FAN Alm 01 | Amber | Blink | CPU module #1 | Cooling fan1 alarm | Check to see if dust is |
|
CPU0 FAN Alm 03 | Amber | Blink | CPU module #1 | Cooling fan2 alarm | accumulated on the |
|
CPU0 FAN Alm 04 | Amber | Blink | CPU module #1 | Cooling fan3 alarm | internal fans. Check also if |
|
the fan cables are |
| |||||
|
|
|
|
|
| |
|
|
|
|
| connected securely. If not |
|
|
|
|
|
| solved by the above, |
|
|
|
|
|
| contact your sales agent. |
|
CPU0 offline | Green | Blink | CPU module #1 | PCI module logically isolated | Start the PCI module by ft |
|
|
|
|
|
| sever utility or dismount |
|
|
|
|
|
| and remount that module. |
|
|
|
|
|
| If not solved by the above, |
|
|
|
|
|
| contact your sales agent. |
|
CPU0 removed | Green | Blink | CPU module #1 | PCI module detached | Dismount and remount the |
|
|
|
|
|
| PCI module. If not solved |
|
|
|
|
|
| by the above, contact your |
|
|
|
|
|
| sales agent. |
|
CPU0 Temp Alm 00 | Amber | Blink | CPU module #1 | Temperature alarm (lower | Check to see if dust is |
|
|
|
|
| limit) | accumulated on the |
|
CPU0 Temp Alm 02 | Amber | Lit | CPU module #1 | Fatal temperature alarm | internal fans. Check also if |
|
|
|
|
| (lower limit) | the fan cables are |
|
|
|
|
|
| connected securely. If not |
|
CPU0 Temp Alm 07 | Amber | Blink | CPU module #1 | Temperature alarm (upper |
| |
solved by the above, |
| |||||
|
|
|
| limit) |
| |
|
|
|
| contact your sales agent. |
| |
CPU0 Temp Alm 09 | Amber | Lit | CPU module #1 | Fatal temperature alarm |
| |
|
| |||||
|
|
|
| (upper limit) |
|
|
|
|
|
|
|
|
|
CPU0 VccpAlm 00 | Amber | Blink | CPU module #1 | CPU operating voltage alarm | Contact your sales agent. |
|
|
|
|
| (lower limit) (VCCP) |
|
|
CPU0 VccpAlm 02 | Amber | Lit | CPU module #1 | Fatal CPU operating voltage |
|
|
|
|
|
| alarm (lower limit) (VCCP) |
|
|
CPU0 VccpAlm 07 | Amber | Blink | CPU module #1 | CPU operating voltage alarm |
|
|
|
|
|
| (upper limit) (VCCP) |
|
|
CPU0 VccpAlm 09 | Amber | Lit | CPU module #1 | Fatal CPU operating voltage |
|
|
|
|
|
| alarm (upper limit) (VCCP) |
|
|
CPU0 Vtt Alm 00 | Amber | Blink | CPU module #1 |
|
| |
|
|
|
| (lower limit) |
|
|
CPU0 Vtt Alm 02 | Amber | Lit | CPU module #1 | Fatal |
|
|
|
|
|
| alarm (lower limit) |
|
|
CPU0 Vtt Alm 07 | Amber | Blink | CPU module #1 |
|
| |
|
|
|
| (upper limit) |
|
|
CPU0 Vtt Alm 09 | Amber | Lit | CPU module #1 | Fatal |
|
|
|
|
|
| alarm (upper limit) |
|
|