Installing and Using Utilities
Check and Clear of MTBF Information
The MTBF information of a component can be viewed or cleared (initialized).
NEC Express5800/ft series manages the MTBF (mean time between failure) of each component. If a fault occurs in a component, the NEC Express5800/ft series calculates the MTBF of the component again. If the calculated value is lower than the
Contact your maintenance personnel if such a symptom as above occurs.
IMPORTANT: A disabled component with the MTBF lower than the threshold can be forcibly enabled by clearing the MTBF. However, contact your maintenance personnel for the forced use of such a component.
To clear the MTBF information of a component with NEC ESMPRO Manager, use the [Maintenance] tree of the component of the [FTServer] tree of the data viewer. Open the tree of the component whose MTBF information is to be cleared and select the [Maintenance] tree.
To clear the MTBF information of a component with the ft server utility, use the utility screen of the component. The table below shows the potential cases in which the MTBF information of a component is to be cleared. Contact your maintenance personnel for clearing MTBF information.
Component | MTBF clear | |
| Remote | Local |
CPU Module | To start the module forcibly after | To start the module forcibly after replacing |
| replacing a module or if MTBF became | a module or if MTBF became lower than |
| lower than the threshold due to | the threshold due to malfunction and |
| malfunction and disabled the module. | disabled the module. |
| Executable in the following module | Executable in the following module state: |
| state (this can be viewed on manager | • Only the red LED is on and the event |
| screen): | |
| indicating that MTBF is lower than the | |
|
| |
| • Broken | threshold is registered in the event log. |
| MTBF is lower than the threshold. |
|
|
|
|
PCI Module | Same as above | Same as above |
|
|
|
Ethernet | To start the module/component forcibly | To start the module/component forcibly |
Adapter | after replacing a module or if MTBF | after replacing a module or if MTBF |
| became lower than the threshold due | became lower than the threshold due to |
| to malfunction and disabled the | malfunction and disabled the |
| module/component. | module/component. |
| Executable in the following module | Executable in the following module state |
| state (this can be viewed on manager | (this can be viewed on manager screen): |
| screen): | • Only the red LED is on and the event |
| • Broken | |
| indicating that MTBF is lower than the | |
| MTBF is lower than the threshold. | threshold is registered in the event log. |
|
|
|
IMPORTANT: You can also clear MTBF information for the PCI module, Ethernet Adapter and SCSI Adapter by unplugging and plugging the live wire of the PCI module.